Argoclima AER522SCL3 Servisní příručka Strana 70

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 82
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 69
66
10-3. Some part of air conditioner does not operate.
10-3-1. Only indoor fan does not run.
10-3-2. Only outdoor fan does not run.
Fan cannot
be turned.
OK
Check fan rotation.
Turn fan gently once or twice by
hand.
Check fan casing
foreign matter on
inside.
Fan motor burnout
or foreign matter in
bearings.
Remove foreign
matter or repair.
Repair or replace.
Measure resistance of indoor fan
motor winding.
Check fan motor capacitor.
Fan cannot
be turned.
OK
Check fan rotation.
Turn fan gently once or twice by
hand.
Check fan casing
foreign matter on
inside.
Fan motor burnout
or foreign matter in
bearings.
Remove foreign
matter or repair.
Repair or replace.
Measure resistance of indoor fan
motor winding.
Check fan motor capacitor.
Measure coil resistance of relay.
(1X)
(Only for models CLR188E38)
Zobrazit stránku 69